1
00:00:00,533 --> 00:00:02,199
iPhone stand by circuit
2
00:00:02,566 --> 00:00:04,799
stand by circuit referred to circuit that
3
00:00:04,800 --> 00:00:07,800
mobile phone has worked before the switch is pressed
4
00:00:08,966 --> 00:00:12,166
damage stand by circuit can cause different faults
5
00:00:13,133 --> 00:00:14,933
the common types of faults in
6
00:00:14,933 --> 00:00:16,699
stand by circuit are short circuit
7
00:00:16,700 --> 00:00:18,333
and electric leakage
8
00:00:21,100 --> 00:00:22,500
short circuit means that
9
00:00:22,500 --> 00:00:25,066
after the memeboard is connected to power cord
10
00:00:25,066 --> 00:00:26,766
the adjustable power supply
11
00:00:26,766 --> 00:00:28,333
directly displays the current
12
00:00:28,333 --> 00:00:30,899
of more than 300 million MPs
13
00:00:31,466 --> 00:00:33,099
electric lickage means that
14
00:00:33,100 --> 00:00:35,566
afternoon board is connected to power cord
15
00:00:35,666 --> 00:00:37,266
the adjustable power supply
16
00:00:37,266 --> 00:00:39,066
directly displays the current between
17
00:00:39,066 --> 00:00:41,133
1 to 300 million MPs
18
00:00:43,600 --> 00:00:44,133
next
19
00:00:44,133 --> 00:00:47,199
let's observe the two fault phenomena through video
20
00:00:48,500 --> 00:00:51,566
let's first observe the current jump of good memeboard
21
00:00:56,533 --> 00:00:57,999
after plugging in the power cord
22
00:00:58,000 --> 00:00:59,533
the current is not displayed
23
00:01:02,966 --> 00:01:05,499
when triggered switch the current will jump
24
00:01:17,100 --> 00:01:19,866
it will jump more than 1A and fall back
25
00:01:21,366 --> 00:01:21,666
then
26
00:01:21,666 --> 00:01:24,399
this current is current phenomena of good memeboard
27
00:01:26,300 --> 00:01:27,566
next let's take a look at
28
00:01:27,566 --> 00:01:29,466
current change of the short circuit
29
00:01:31,166 --> 00:01:32,966
after the power cord sparkled
30
00:01:32,966 --> 00:01:36,899
the current directly reaches about 500 million MPs
31
00:01:40,333 --> 00:01:42,466
after this meaning board is connected to the power
32
00:01:42,466 --> 00:01:46,066
court the current directly reaches 1.7 a
33
00:01:48,000 --> 00:01:50,700
after this meaning board is connected to power court
34
00:01:50,700 --> 00:01:53,566
the current directly reaches 4.9 a
35
00:01:54,100 --> 00:01:56,066
and the voltage is pulled down
36
00:01:57,666 --> 00:02:00,466
if current about 300 million MPs
37
00:02:00,533 --> 00:02:02,466
it belongs to the short circuit
38
00:02:02,866 --> 00:02:05,266
there are many names in the actual midness
39
00:02:05,266 --> 00:02:06,533
like high current
40
00:02:06,700 --> 00:02:10,100
short circuit during connection or big short circuit
41
00:02:10,366 --> 00:02:12,666
actually they refer to the same fold
42
00:02:12,800 --> 00:02:15,200
and their midness methods are the same
43
00:02:16,900 --> 00:02:19,733
let's look at current change of the electric leakage
44
00:02:23,400 --> 00:02:25,066
after the power cord sparkled
45
00:02:25,066 --> 00:02:27,133
the current showed 6 million peers
46
00:02:33,533 --> 00:02:35,166
after the Power Court sparkled
47
00:02:35,166 --> 00:02:37,699
the current shows 23 million MPs
48
00:02:40,000 --> 00:02:41,600
after the power chords buckled
49
00:02:41,600 --> 00:02:43,966
the currential 70 million MPs
50
00:02:45,166 --> 00:02:47,866
we just saw that these three currents are all
51
00:02:47,866 --> 00:02:49,799
below 300 million MPs
52
00:02:50,000 --> 00:02:52,266
they belong to the electric leakage
53
00:02:52,333 --> 00:02:54,699
and their midness methods are the same
54
00:02:59,266 --> 00:03:00,699
through the video just now
55
00:03:00,700 --> 00:03:01,066
have you
56
00:03:01,066 --> 00:03:03,999
Learned to distinguish the fault of the standby circuit