• Learning center

93. No trigger maintenance process 3
In this video we're going to learn about the no trigger repair process.
Detail
Comments

1

00:00:01,000 --> 00:00:02,733

iPhone trigger circuit

2

00:00:03,266 --> 00:00:07,633

In this video we're going to learn about the no trigger repair process

3

00:00:08,766 --> 00:00:13,366

In the maintenance, we are going to repair from the simple to the complex step by step

4

00:00:16,000 --> 00:00:18,466

No trigger maintenance process 3

5

00:00:19,133 --> 00:00:23,633

After we eliminate short circuit or broken wire of the switch pin,

6

00:00:24,100 --> 00:00:27,366

we need to measure whether the standby power supply is normal

7

00:00:29,666 --> 00:00:34,500

Because the power supply provides the operating voltage to the CPU and the switch pins,

8

00:00:34,800 --> 00:00:38,333

an abnormal voltage will cause the power not to start

9

00:00:38,566 --> 00:00:39,966

So let's measure it

10

00:00:41,166 --> 00:00:44,133

Let's start by opening the bitmap of the iPhone 6

11

00:00:44,600 --> 00:00:47,900

Select the Find button, select the search signal,

12

00:00:48,400 --> 00:00:50,900

and enter PP1V8_ALWAYS

13

00:00:54,266 --> 00:00:57,866

We can measure the standby power on the yellow positions in the bitmap

14

00:00:58,900 --> 00:01:01,466

After the mainboard buckles the boot cable,

15

00:01:01,700 --> 00:01:05,466

we measure PP1V8_ALWAYS in the reverse side

16

00:01:06,433 --> 00:01:10,033

According to the bitmap, we find the measuring position

17

00:01:11,133 --> 00:01:15,033

Now we can see that it has a voltage of 1.78V

18

00:01:15,733 --> 00:01:19,700

This is the standby power supply after the power cord is connected

19

00:01:20,500 --> 00:01:22,166

For the actual measurement,

20

00:01:22,300 --> 00:01:26,666

the measuring point is inside the shield, so we can cut it off

21

00:01:27,766 --> 00:01:30,733

If the voltage is abnormal during the measurement,

22

00:01:31,066 --> 00:01:33,566

we will replace the power supply directly

23

00:01:34,633 --> 00:01:36,633

After replacing the power supply,

24

00:01:37,433 --> 00:01:42,133

if the voltage is not normal, it indicates that the CPU is damaged

25

00:01:42,466 --> 00:01:44,966

We have to return the machine to the customer

26

00:01:46,333 --> 00:01:48,566

So that's all for this lesson

No comments yet
Come and write your comments
Links: