1
00:00:00,100 --> 00:00:05,433
Hello everyone, today we are going to understand the method of brushing T2 and error instructions
2
00:00:06,266 --> 00:00:11,566
First of all, the T2 brush method is available on Apple's official website
3
00:00:13,266 --> 00:00:16,733
All you have to do is follow the official step-by-step instructions
4
00:00:19,366 --> 00:00:22,900
Next, we will introduce the error in the process of brushing T2锛?
5
00:00:22,933 --> 00:00:24,366
and how to solve it
6
00:00:26,266 --> 00:00:29,933
The first step is to install the latest version of the MAC system
7
00:00:30,166 --> 00:00:32,033
apple configurator 2
8
00:00:35,766 --> 00:00:39,366
The system is not up to date and will report error 10
9
00:00:42,166 --> 00:00:46,133
Second, the computer must enter the DFU mode
10
00:00:48,066 --> 00:00:54,066
Third, in the process of brushing T2, it will first verify the lower layer of T2
11
00:00:56,000 --> 00:00:59,866
At this point, the working conditions of T2 should be normal
12
00:01:00,866 --> 00:01:04,733
Next, verify the upper level RAM of T2
13
00:01:05,433 --> 00:01:09,866
The upper layer will report error 4014 if there is a problem
14
00:01:12,033 --> 00:01:18,600
After the upper layer has no problems, the device on the I2C0 bus of T2 will be verified,
15
00:01:20,500 --> 00:01:23,400
mainly to verify whether the adapter has a boost
16
00:01:24,300 --> 00:01:28,933
Verify the CD3215 or CD3217 chip
17
00:01:29,400 --> 00:01:34,800
If there is a problem, the error 4014 will be reported immediately
18
00:01:39,400 --> 00:01:44,266
After the I2C0 bus of T2 is verified, the hard disk is verified
19
00:01:47,033 --> 00:01:48,733
When verifying the hard drive,
20
00:01:49,233 --> 00:01:51,100
it reads and then writes
21
00:01:51,900 --> 00:01:53,766
The disk is read first
22
00:01:53,900 --> 00:01:59,133
If there is a problem during the read process, error 4014 is displayed,
23
00:01:59,866 --> 00:02:04,733
which generally indicates that the underlying data of the disk is damaged
24
00:02:05,633 --> 00:02:10,833
Write to hard disk, error 9 or 6 will be reported if there is a problem
25
00:02:11,600 --> 00:02:14,966
Error 6 is mostly the hard disk installed backwards,
26
00:02:16,233 --> 00:02:21,000
error 9 is reported, if the screen is on, the hard disk is broken
27
00:02:22,500 --> 00:02:29,500
Error 9 is reported, if the screen is not displayed, there is usually a CPU or PCH problem
28
00:02:29,833 --> 00:02:32,200
Error 9 is the most difficult to fix
29
00:02:33,466 --> 00:02:41,966
After the hard disk is verified, if the T2 logic code chip is verified, error 14 or 27 will be displayed
30
00:02:44,233 --> 00:02:53,266
After verifying the logic chip, verify CPU and PCH, error 75 or 78 will be reported if there is any problem
31
00:02:54,433 --> 00:02:56,566
Next, verify the touchpad
32
00:02:57,133 --> 00:03:03,433
If there is a problem, error -1 will be reported, and the touchpad will not be brushed
33
00:03:04,933 --> 00:03:12,366
Next, we have to verify the fingerprint, and if there is a problem, error 1 will be reported
34
00:03:13,666 --> 00:03:17,366
Ok, here is how to brush T2 and the error description