Hello everyone, today we will learn about the vertical control area
2
00:00:03,933 --> 00:00:06,666
and software buttons in the oscilloscope panel
3
00:00:09,633 --> 00:00:12,000
Let's take a look at the software button first
4
00:00:12,400 --> 00:00:15,900
The software button refers to the row of buttons around the screen
5
00:00:16,233 --> 00:00:20,933
For example, if I want to change the automatic trigger mode to the normal trigger mode,
6
00:00:21,300 --> 00:00:23,100
I can click this button
7
00:00:26,200 --> 00:00:30,066
Press the button next to the slope to change the rising edge and falling edge
8
00:00:32,666 --> 00:00:35,733
Second, this is the print and store button
9
00:00:37,666 --> 00:00:41,600
When the green light is on, press this button to store the waveform
10
00:00:45,000 --> 00:00:49,233
When the light is off, we press this button, it is the printing function
11
00:00:50,000 --> 00:00:55,433
The third button, this is the probe detection button, this function is generally rarely used
12
00:00:56,900 --> 00:01:00,200
Fourth, this is the probe compensation contact point
13
00:01:02,266 --> 00:01:07,366
When calibrating the probe, you need to place the probe on the probe compensation contact point
14
00:01:07,366 --> 00:01:09,333
to adjust the probe compensation
15
00:01:14,366 --> 00:01:17,966
The fifth is the USB interface, used to connect the U disk
16
00:01:20,366 --> 00:01:26,333
Next, let's take a look at the function introduction of some buttons and knobs in the vertical control area
17
00:01:26,733 --> 00:01:30,966
The first small knob, this is the vertical position adjustment of channel 1
18
00:01:31,633 --> 00:01:35,000
The current position of channel 1 is at the middle 0 position
19
00:01:35,366 --> 00:01:40,500
By adjusting this knob, the vertical position of channel 1 can be moved up and down
20
00:01:43,200 --> 00:01:47,566
The second small knob, this is the vertical position adjustment of channel 2
21
00:01:51,133 --> 00:01:53,733
The third is the opening and closing of channel 1,
22
00:01:54,100 --> 00:01:56,733
and it is also the menu setting of channel 1
23
00:01:59,466 --> 00:02:03,700
After pressing this button, you can see the setting menu of channel 1
24
00:02:11,733 --> 00:02:17,466
This CH2 is the opening and closing of channel 2, and it is also the menu setting of channel 2
25
00:02:22,133 --> 00:02:26,466
The button in the middle is a vertical menu, which is generally not used
26
00:02:28,333 --> 00:02:32,066
The sixth big knob is the volts/ grid adjustment of channel 1
27
00:02:35,966 --> 00:02:38,766
The current channel 1 is set to 1V per grid
28
00:02:40,333 --> 00:02:44,200
The seventh big knob is the volts/ grid adjustment of channel 2
29
00:02:44,900 --> 00:02:47,733
The current channel 2 is set to 1V per grid
30
00:02:48,666 --> 00:02:53,666
The 8th and 9th, respectively are channel 1 and channel 2 probe input terminals,
31
00:02:54,100 --> 00:02:56,333
used to connect oscilloscope probes
32
00:02:57,333 --> 00:03:02,333
Ok, here's an introduction to the oscilloscope's vertical control area and software buttons