1
00:00:00,333 --> 00:00:07,466
In this lesson, we will learn about the function introduction of the horizontal control area
2
00:00:09,700 --> 00:00:12,133
First look at the horizontal control area
3
00:00:13,333 --> 00:00:17,300
In the horizontal control area, there are two buttons and two knobs
4
00:00:18,066 --> 00:00:19,933
Take a look at the first little knob
5
00:00:20,366 --> 00:00:25,366
This is horizontal position adjustment, also known as trigger position adjustment
6
00:00:25,933 --> 00:00:30,900
When adjusting this knob, the arrow in the middle of the screen will follow the movement
7
00:00:33,500 --> 00:00:35,433
In the process of measurement and use,
8
00:00:36,033 --> 00:00:40,100
we need to adjust the trigger position to the position of 0 in the middle of the screen
9
00:00:41,666 --> 00:00:46,866
The second button is the horizontal control menu, this function is generally rarely used
10
00:00:49,433 --> 00:00:52,833
The third is to quickly return to zero in the horizontal position
11
00:00:54,433 --> 00:01:00,600
For example, we have adjusted this horizontal position to the left of the screen, or beyond the screen range
12
00:01:03,000 --> 00:01:06,133
You can press the horizontal position fast zero button,
13
00:01:08,200 --> 00:01:12,133
and its arrow will quickly return to the zero position in the middle of the screen
14
00:01:16,800 --> 00:01:20,333
The fourth is the big knob, which is used to adjust the time base,
15
00:01:20,700 --> 00:01:24,000
that is, the adjustment of the time in the middle of the screen
16
00:01:27,233 --> 00:01:29,566
This is the time base adjustment knob
17
00:01:33,166 --> 00:01:39,033
Fifth, this is the input terminal of the external trigger channel, which is generally not used
18
00:01:39,400 --> 00:01:42,733
Next, let's look at the trigger control area
19
00:01:44,000 --> 00:01:47,466
There are 1 knob and 4 buttons in the trigger control area
20
00:01:47,766 --> 00:01:50,766
The first knob is the adjustment knob for the trigger level
21
00:01:51,266 --> 00:01:56,300
When turning this knob, you can change the size of the trigger level in the lower right corner
22
00:02:03,866 --> 00:02:07,133
The second button, this is the trigger settings menu
23
00:02:08,000 --> 00:02:10,633
Its source (trigger channel) can be changed by software button,
24
00:02:11,000 --> 00:02:15,766
and can be set as channel 1, channel 2 or external trigger channel, etc.
25
00:02:18,366 --> 00:02:23,866
Slope, also called edge type, is generally set to rising edge or falling edge
26
00:02:24,266 --> 00:02:27,800
When measuring the power supply, the rising edge is generally used
27
00:02:28,466 --> 00:02:33,866
When measuring power-down, the low-level effective signal is generally used to measure the falling edge
28
00:02:34,066 --> 00:02:37,366
Trigger mode, here are automatic and normal
29
00:02:39,600 --> 00:02:44,466
If we want to use the single trigger function, we need to press the single trigger button next to it,
30
00:02:48,533 --> 00:02:50,300
the coupling is set to DC
31
00:02:51,533 --> 00:02:56,366
Next, there is a mandatory trigger here, which is generally not used
32
00:02:58,466 --> 00:03:03,600
Next, there is a trigger line here, showing the position of the vertical starting point
33
00:03:04,233 --> 00:03:06,766
This function is generally not commonly used
34
00:03:07,133 --> 00:03:12,400
Ok, this is the function introduction of horizontal control area and trigger control area