1
00:00:00,900 --> 00:00:05,600
This lesson is about the maintenance for the prompt of the battery anomaly
2
00:00:06,233 --> 00:00:10,833
First look at the fault phenomenon that indicates abnormal charging
3
00:00:11,466 --> 00:00:15,933
Plug in the charging cable to charge the phone, it will prompt abnormal charging,
4
00:00:15,933 --> 00:00:18,500
please consult the customer service center
5
00:00:19,000 --> 00:00:20,966
this is a malfunction
6
00:00:21,533 --> 00:00:25,233
Another phenomenon is that when the charging cable is plugged in,
7
00:00:25,233 --> 00:00:30,600
it prompts that the battery contact is abnormal, please consult the customer service center
8
00:00:31,000 --> 00:00:33,700
It is common to have these two symptoms
9
00:00:34,200 --> 00:00:38,666
The solution is to find the information detection pin of the battery
10
00:00:39,533 --> 00:00:44,266
The detection circuit of the battery is from the battery to the battery holder
11
00:00:45,433 --> 00:00:51,366
The battery holder transmits the battery information to the charging chip or the main power supply
12
00:00:52,033 --> 00:00:57,900
The charging chip feeds back the information detected by the main power supply to the CPU
13
00:01:00,000 --> 00:01:02,666
There is a chip on the battery board
14
00:01:03,133 --> 00:01:08,066
The ID pin is used to transmit signals through the chip on the battery board
15
00:01:09,566 --> 00:01:12,500
The battery holder is just a connector
16
00:01:13,133 --> 00:01:19,100
The connection seat is to contact the ID pin information on the battery seat through the shrapnel
17
00:01:20,966 --> 00:01:27,266
Android mobile phones generally detect battery information by charging chips or main power chips
18
00:01:27,766 --> 00:01:31,500
Next, let's look at Huawei's battery detection circuit
19
00:01:31,900 --> 00:01:35,166
First look at what components are in this circuit
20
00:01:35,566 --> 00:01:40,233
The first is the battery holder, the battery holder is to install the battery,
21
00:01:40,233 --> 00:01:42,200
we regard it as a battery
22
00:01:42,866 --> 00:01:48,033
The battery holder leads to the main power supply through a 1000 ohm resistor
23
00:01:48,966 --> 00:01:53,800
The main power supply is responsible for detecting the information of the battery,
24
00:01:54,233 --> 00:01:56,500
and its code name is BATT_ID
25
00:01:57,233 --> 00:02:01,333
In this circuit, this side is powered by 1.8 volts
26
00:02:02,500 --> 00:02:10,400
The 1.8 volt power supply provides a voltage of about 1.8 volts to this signal line through a 68 kohm resistor
27
00:02:11,066 --> 00:02:14,766
After the BATT_ID pin gets a voltage of 1.8 volts,
28
00:02:15,166 --> 00:02:19,166
it reaches the main power supply through a 1K ohm resistor
29
00:02:20,733 --> 00:02:27,033
At this time, the large power supply detects the information of the battery through this signal line
30
00:02:27,600 --> 00:02:34,900
During maintenance, we should pay attention to whether the resistors R1506 and R1502 are abnormal
31
00:02:36,333 --> 00:02:40,533
If the resistor R1506 is damaged or falsely welded,
32
00:02:41,066 --> 00:02:47,466
the BATT_ID pin will not have a voltage of 1.8 volts, and the entire circuit will fail
33
00:02:48,300 --> 00:02:53,966
The detection pins are usually on the 4 smaller pins in the middle of the battery holder
34
00:02:55,466 --> 00:02:59,133
This is Huawei's battery detection circuit principle
35
00:02:59,766 --> 00:03:01,666
That's all for this lesson