• Learning center

153. Maintenance for independent baseband failure 2
153. Maintenance for independent baseband failure 2
Detail
Comments

1

00:00:00,366 --> 00:00:06,633

This lesson talks about the maintenance for no baseband fault of mobile phones with independent baseband

2

00:00:07,233 --> 00:00:14,333

After performing the above two steps and re-soldering the baseband, the power-on test still has no baseband

3

00:00:16,100 --> 00:00:24,200

The maintenance method is to first measure the ground value of the main power supply of the baseband to see if it is low or short-circuited

4

00:00:25,766 --> 00:00:30,633

If it is a short circuit, check the capacitor or chip connected to the line

5

00:00:31,100 --> 00:00:36,133

Generally, the capacitance is considered, and then the chip is considered

6

00:00:37,566 --> 00:00:40,400

If there is no short circuit to the ground value,

7

00:00:40,800 --> 00:00:46,866

remove the baseband CPU and measure the solder joint of the chip where the baseband CPU leads to

8

00:00:47,666 --> 00:00:50,333

Usually measure the ground value to determine

9

00:00:50,333 --> 00:00:54,700

whether there is an open circuit or a short circuit in the signal channel

10

00:00:56,333 --> 00:01:00,000

If there is a short circuit in the signal leading to other chips,

11

00:01:00,333 --> 00:01:04,133

generally remove the capacitor connected to the line first

12

00:01:05,733 --> 00:01:09,300

If there is still a short circuit, then measure the chip

13

00:01:11,066 --> 00:01:17,233

Among these chips, the radio frequency chip, baseband power supply or clock chip can be replaced,

14

00:01:17,600 --> 00:01:20,366

but the large CPU cannot be replaced

15

00:01:23,200 --> 00:01:29,466

If OL appears in the measured ground value, check whether there is a capacitor connected in the line

16

00:01:32,066 --> 00:01:35,733

Because in the line where the capacitors are connected in series,

17

00:01:36,233 --> 00:01:41,700

it is normal to measure the value of infinity to the ground, this should be paid attention to

18

00:01:43,433 --> 00:01:48,500

If there is no capacitor in the line, first resolder the chip in the line

19

00:01:51,033 --> 00:01:57,333

After re-welding, if the ground value returns to normal, it means that the fault has been repaired

20

00:01:58,566 --> 00:02:04,700

If the ground value is still infinite after re-soldering, you need to replace the chip in the circuit

21

00:02:07,800 --> 00:02:11,733

The baseband power supply chip and the clock chip can be replaced,

22

00:02:11,733 --> 00:02:15,933

but the large CPU cannot be replaced and can only be re-soldered

23

00:02:16,666 --> 00:02:21,966

This is the maintenance for no baseband fault of mobile phones with independent baseband

24

00:02:22,733 --> 00:02:24,700

That's all for this lesson

No comments yet
Come and write your comments
Links: