1
00:00:00,366 --> 00:00:06,633
This lesson talks about the maintenance for no baseband fault of mobile phones with independent baseband
2
00:00:07,233 --> 00:00:14,333
After performing the above two steps and re-soldering the baseband, the power-on test still has no baseband
3
00:00:16,100 --> 00:00:24,200
The maintenance method is to first measure the ground value of the main power supply of the baseband to see if it is low or short-circuited
4
00:00:25,766 --> 00:00:30,633
If it is a short circuit, check the capacitor or chip connected to the line
5
00:00:31,100 --> 00:00:36,133
Generally, the capacitance is considered, and then the chip is considered
6
00:00:37,566 --> 00:00:40,400
If there is no short circuit to the ground value,
7
00:00:40,800 --> 00:00:46,866
remove the baseband CPU and measure the solder joint of the chip where the baseband CPU leads to
8
00:00:47,666 --> 00:00:50,333
Usually measure the ground value to determine
9
00:00:50,333 --> 00:00:54,700
whether there is an open circuit or a short circuit in the signal channel
10
00:00:56,333 --> 00:01:00,000
If there is a short circuit in the signal leading to other chips,
11
00:01:00,333 --> 00:01:04,133
generally remove the capacitor connected to the line first
12
00:01:05,733 --> 00:01:09,300
If there is still a short circuit, then measure the chip
13
00:01:11,066 --> 00:01:17,233
Among these chips, the radio frequency chip, baseband power supply or clock chip can be replaced,
14
00:01:17,600 --> 00:01:20,366
but the large CPU cannot be replaced
15
00:01:23,200 --> 00:01:29,466
If OL appears in the measured ground value, check whether there is a capacitor connected in the line
16
00:01:32,066 --> 00:01:35,733
Because in the line where the capacitors are connected in series,
17
00:01:36,233 --> 00:01:41,700
it is normal to measure the value of infinity to the ground, this should be paid attention to
18
00:01:43,433 --> 00:01:48,500
If there is no capacitor in the line, first resolder the chip in the line
19
00:01:51,033 --> 00:01:57,333
After re-welding, if the ground value returns to normal, it means that the fault has been repaired
20
00:01:58,566 --> 00:02:04,700
If the ground value is still infinite after re-soldering, you need to replace the chip in the circuit
21
00:02:07,800 --> 00:02:11,733
The baseband power supply chip and the clock chip can be replaced,
22
00:02:11,733 --> 00:02:15,933
but the large CPU cannot be replaced and can only be re-soldered
23
00:02:16,666 --> 00:02:21,966
This is the maintenance for no baseband fault of mobile phones with independent baseband
24
00:02:22,733 --> 00:02:24,700
That's all for this lesson