1
00:00:00,733 --> 00:00:05,200
This lesson is about the maintenance steps of the unreadable SIM card
2
00:00:05,766 --> 00:00:11,266
After excluding the above 3 steps, it is necessary to proceed to the fourth step
3
00:00:11,700 --> 00:00:15,500
Install the SIM card, do not need to turn on the mobile phone,
4
00:00:15,500 --> 00:00:19,500
to measure the ground value of the detection signal of the SIM card
5
00:00:20,033 --> 00:00:24,433
What you need to know here is that after the SIM card is installed in the mobile phone,
6
00:00:24,433 --> 00:00:27,400
the card detection signal will no longer be grounded,
7
00:00:27,400 --> 00:00:31,500
and there will be a normal ground value, generally above 300
8
00:00:32,366 --> 00:00:36,600
In the real thing, this copper piece is its detection pin
9
00:00:39,600 --> 00:00:41,700
When the SIM card is not inserted,
10
00:00:41,700 --> 00:00:45,566
the detection pin is in contact with the grounding shrapnel
11
00:00:48,200 --> 00:00:50,466
Look at the picture on the right
12
00:00:51,100 --> 00:00:56,833
The shrapnel below is the ground wire, and the shrapnel above is actually the detection signal
13
00:00:58,000 --> 00:01:02,466
When the SIM card is not inserted, the two shrapnels are in contact,
14
00:01:02,466 --> 00:01:05,500
and the detection signal is actually grounded
15
00:01:08,933 --> 00:01:12,900
Look at the two pictures on the left, when the SIM card is inserted,
16
00:01:12,900 --> 00:01:16,466
the ground wire and the detection signal are disconnected
17
00:01:17,533 --> 00:01:19,900
Check out this enlarged image
18
00:01:20,433 --> 00:01:24,966
This is the detection signal, and the one below is the ground wire
19
00:01:27,300 --> 00:01:33,766
The shrapnel of the ground wire is pushed away, and the detection signal is no longer grounded after the push-off,
20
00:01:33,766 --> 00:01:35,866
and it has a normal ground value
21
00:01:36,533 --> 00:01:42,433
So when we measure the ground value of the detection signal, we must insert the SIM card
22
00:01:43,033 --> 00:01:48,266
If there is no abnormality in the ground value measured, proceed to the next step
23
00:01:48,800 --> 00:01:55,000
If there is a short circuit to ground, first remove the capacitor or diode connected to this line
24
00:01:56,833 --> 00:02:00,666
Generally, diodes are rarely designed for this circuit.
25
00:02:01,566 --> 00:02:07,566
After excluding the above components, consider the chip that the detection signal leads to
26
00:02:08,366 --> 00:02:10,633
So where does the heartbeat go?
27
00:02:11,400 --> 00:02:15,666
Generally it leads to baseband CPU or big CPU
28
00:02:16,633 --> 00:02:21,233
When it is still short-circuited after removing the capacitors and diodes
29
00:02:21,900 --> 00:02:26,833
it is necessary to re-solder the baseband CPU or large CPU
30
00:02:28,033 --> 00:02:31,766
If there is an infinite OL, it is an open circuit
31
00:02:32,366 --> 00:02:37,700
At this time, first observe whether the seat has been welded, and there are false welds
32
00:02:38,566 --> 00:02:45,000
If it has not been soldered, you need to re-solder the baseband CPU or the main CPU at this time
33
00:02:45,866 --> 00:02:50,800
If it is invalid after soldering, basically either the board layer is disconnected,
34
00:02:50,800 --> 00:02:54,266
or the CPU or baseband CPU is damaged
35
00:02:57,033 --> 00:03:03,366
If the CPU and baseband CPU are damaged, it is very serious and basically irreparable
36
00:03:03,900 --> 00:03:05,933
That's all for this lesson